Installation guide

E4G-200 Series Cell Site Routers
E4G Series Routers Hardware Installation Guide
17
E4G-200 Series CLK Module
An optional clock module (Figure 4) for both E4G-200 Series routers provides timing based on either of
the following protocols:
ITU-T Synchronous Ethernet (SyncE) protocol
Precision Time Protocol based on the IEEE specification 1588v2
The clock module has four mini-BNC connectors providing Sync In/Sync Out timing interfaces and an
RJ-45 connector that provides an RS-422 BITS-IN interface. Clock modules can be installed or removed
without powering down the router, although a system reboot is required to initialize the module.
Figure 4: E4G-200 Series Clock Module
E4G-200 Series F16T1E1 Module
The F16T1E1 module for both E4G-200 Series router provides 16 T1/E1 ports implemented as RJ-45
connectors (Figure 5. These support circuit emulations via industry-standard pseudowires, allowing the
transformation of TDM cell sites to Ethernet/IP/MPLS cell sites. T1/E1 modules can be installed
or removed without powering down the router, although a system reboot is required to initialize
the module.
Figure 5: E4G-200 Series F16T1E1 Module
CSR_012
1 32
1 = LED
2 = Sync In/Sync Out interfaces
3 = BITS IN interface
CSR_015
1 2
1 = LEDs
2 = T1/E1 ports