Installation guide
E4G-400 Cell Site Aggregation Router
E4G Series Routers Hardware Installation Guide
119
E4G-400 Router with E4G-B16T1E1 Module (AC Power)
Nominal input ratings 100 to 240 V , 50/60 Hz, 5 A
Maximum Input current 5 A @ 100 V (low-line)
2.5 A @ 240 V (high-line)
Heat dissipation, 91 W, 311 BTU/hr (with 1 power supply)
Power consumption 91 W, 311 BTU/hr (with 1 power supply)
E4G-400 Router with XGM3S-2sf Option Card and XGM3SB-4sf Option Card (AC Power)
Nominal input ratings 100 to 240 V , 50/60 Hz, 5 A
Maximum Input current 5 A @ 100 V (low-line)
2.5 A @ 240 V (high-line)
Heat dissipation 100 W, 341 BTU/hr (with 1 power supply)
Power consumption 100 W, 341 BTU/hr (with 1 power supply)
E4G-400 Router with XGM3S-2sf Option Card and E4G-B16T1E1 Module (AC Power)
Nominal input ratings 100 to 240 V , 50/60 Hz, 5 A
Maximum Input current 5 A @ 100 V (low-line)
2.5 A @ 240 V (high-line)
Heat dissipation 99 W, 339 BTU/hr (with 1 power supply)
Power consumption 99 W, 339 BTU/hr (with 1 power supply)
E4G-400 Router with XGM3S-2xf Option Card and XGM3SB-4sf Module (AC Power)
Nominal input ratings 100 to 240 V , 50/60 Hz, 5 A
Maximum Input current 5 A @ 100 V (low-line)
2.5 A @ 240 V (high-line)
Heat dissipation 104 W, 355 BTU/hr (with 1 power supply)
Power consumption 104 W, 355 BTU/hr (with 1 power supply)
E4G-400 Router with XGM3S-2xf Option Card and E4G-B16T1E1 Module (AC Power)
Nominal input ratings 100 to 240 V , 50/60 Hz, 5 A
Maximum Input current 5 A @ 100 V (low-line)
2.5 A @ 240 V (high-line)
Heat dissipation 104 W, 355 BTU/hr (with 1 power supply)
Power consumption 104 W, 355 BTU/hr (with 1 power supply)
Power (with DC Power Supplies)
E4G-400 Router with No Installed Optional Ports (DC Power)
Nominal input ratings 40 to 72 V , 9 A
Maximum Input current 7 A @ 48 V (low-line)
5.6 A @ 60 V (high-line)
Heat dissipation 87 W, 297 BTU/hr (with 1 power supply)
Power consumption 87 W, 297 BTU/hr (with 1 power supply)