Installation guide
Appendix B: Technical Specifications
E4G Series Routers Hardware Installation Guide
116
1999/5/EC R&TTE
2006/95/EC Low Voltage Directive
2004/108/EC EMC Directive
2002/96/EC WEEE
2002/95/EC RoHS
China RoHS Order No. 39
Country-specific (see “Conformity
Statements” on page 133)
Canada, ICES-003, (IC)
Japan, Class A, (VCCI)
Taiwan, CNS 13438(95) Class A, CNS 14336-1(10), (BSMI)
Australia/New Zealand, C-Tick (ACMA)
South Korea: KN22, KN24 (KCC)
Brazil, Res 442, (ANATEL)
Mexico, NOM-19 (NRTL)
Russia (GOST-R)
IEEE 802.3 Media Access Standards
IEEE 802.3ab 1000BASE-T
Environmental Data
Environmental Standards EN/ETSI 300 019-2-1 v2.1.2 (2009-09) - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.2.1 (2011-11) - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.2.2 (2003-04) - Class 3.1e Operational
EN/ETSI 300 753 (2009-07) - Acoustic Noise
Operating conditions Temperature range: –40° C to +65° C (–40° to 149° F)
Humidity: 5% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Shock (half sine): 30 m/s
2
, 60 shocks in each direction
Random vibration: 3 to 500 MHz @ 1.5 G rms
Storage & transportation
conditions (packaged)
Temperature: –40° C to 70° C (–40° F to 158° F)
Humidity: 10% to 95% relative humidity, non-condensing
Packaged shock (half sine): 180 m/s
2
, 100 shocks in each
direction
Packaged sine vibration: 5 to 62 Hz @ velocity 5 mm/s,
62 to 500 Hz @ 0.2 G
Packaged random vibration: 5 to 20 Hz @ 1.0 ASD
20 to 200 Hz @–3 dB/octave
14 drops minimum on sides & corners @ 42 inches (<15 kg box)
Sound power
(In accordance with ISO
9296:1988, ISO 3744:2010(E),
ISO 7779:2010(E) ETSI 300
753:2007(E) )
Low: <40°C = 5.2 bels(A) (L
WAd
) Declared Sound Power
Medium: 40°C to 50°C = 6.3 bels(A) (L
WAd
) Declared Sound Power
High: >50°C = 7.2 bels(A) (L
WAd
) Declared Sound Power
Table 13: E4G-200-12x Cell Site Router Technical Specifications (Continued)