Nominal Input Current 0.95 A @ –48 V
2.2 A @ +24 V
Inrush Current 35 A at 72 V peak
DC Voltage Input Range –22 to 60 V
DC Power Supply Input Socket 3-pin terminal block. Refer to instructions on page 51.
Minimum wire size 14 AWG (1.5 mm
2
) copper stranded
E4G-200 router with no installed optional modules
Input current 0.68 A @ +24 V
0.52 A @ –48 V
Heat dissipation 33 W, 113 BTU/hr
Power consumption 33 W, 113 BTU/hr
E4G-200 router with clock module
Input current 0.83 A @ +24V
0.64 A @ –48 V
Heat dissipation 40 W, 137 BTU/hr
Power consumption 40 W, 137 BTU/hr
E4G-200 router with T1/E1 module
Input current 0.89 A @ +24 V
0.69 A @ –48 V
Heat dissipation 43 W, 147 BTU/hr
Power consumption 43 W, 147 BTU/hr
E4G-200 router with clock module and T1/E1 module
Input current 1.02 A @ +24 V
0.78 A @ –48 V
Heat dissipation 49 W, 167 BTU/hr
Power consumption 49 W, 167 BTU/hr
Safety Standards
North American Safety UL 60950-1:2007 2nd Ed., Listed Device (US)
CSA 22.2 #60950-1-03 2nd Ed. 2006-07 (Canada)
Complies with FCC 21 CFR Chapter 1, Subpart J (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety CB Scheme IEC 60950-1: 2005 2nd Ed.+National Differences
IEC/EN 60825-1:2007 (Lasers Safety)
IEC/EN 60825-2:2004+A2:2010 (Optic Fiber Systems)
International Safety GS-TUV Mark EN 60950-1:2006 2nd Ed.
AS/NZS 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC EN 55022:2010 Class A
EN 55024:2010 Class A includes EN 61000-4-2, 3, 4, 5, 6, 11
EN 55011:2009+A1:2010
EN 61000-3-2,8-2006+A2:2009 (Harmonics)
EN 61000-3-3 2008 (Flicker)
EN 61000-6-4:2007 (Emissions for Industrial, Scientific & Medical)
EN 61000-6-2:2005 (Immunity for Industrial, Scientific & Medical)
Table 12: E4G-200 Cell Site Router Technical Specifications (Continued)