Technical data
Configuring and Managing Routers with Site Manager
B-30 117347-A Rev. A
Parameter: Slot Lower Bound
Default: 0
Options: 0 to 14
Function: Along with the Slot Upper Bound parameter, specifies the slot or range of
slots on which you want to filter the log messages for this entity. (In the
case of ASN routers, this parameter specifies the module for the particular
slot because an ASN router is considered a slot.)
Instructions: To specify a range of slots, type the lower number of the range in this
parameter. You then type the upper number of the range in the Slot Upper
Bound parameter.
The values you type for lower and upper bound are included in the range.
For example, if you specify a lower bound of 1 and an upper bound of 4,
syslog forwards all messages that occur on slots 1 through 4, inclusive.
The syslog facility ignores event messages that occur on all other slots.
To filter events for a specific slot, type the slot number in this field. Be
sure to type the same number in the Slot Upper Bound field. For example,
to forward only the log messages that occur on slot 2, type 2 in this
parameter and in the Slot Upper Bound parameter.
If you do not want to use this filter, accept the default, 0. Be sure to accept
the default in the Slot Upper Bound parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.10