Technical data

Configuring and Managing Routers with Site Manager
B-28 117347-A Rev. A
Parameter: Log Evt Upper Bound
Default: 255
Options: 0 to 255
Function: Along with the Log Evt Lower Bound parameter, specifies the event
number (code) or range of event numbers (for the current filter) that you
want to forward to the remote host
Instructions: To specify a range of event numbers, type the upper number of the range
in this field. You must specify the lower number of the range in the Log
Evt Lower Bound parameter.
The values you type for lower and upper bound are included in the range.
For example, if you specify a lower bound of 2 and an upper bound of 7,
syslog forwards all messages that are of event codes 2 through 7,
inclusive. The syslog facility ignores all other event messages.
To filter a specific event code, type the event code in this parameter. You
must type the same event code in the Log Evt Lower Bound parameter.
For example, to forward only the log messages that have an event code of
10, type 10 in this field and in the Log Evt Lower Bound parameter.
If you do not want to filter by event code, accept the default, 255. Be sure
to accept the default in the Log Evt Lower Bound parameter.
If you use the wildcard filter entry, 255, the syslog facility ignores this
parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.8