Technical data

Site Manager Parameters
117347-A Rev. A B-27
Parameter: Log Evt Lower Bound
Default: 0
Options: 0 to 255
Function: Along with the Log Evt Upper Bound parameter, specifies the event
number (code) or range of event numbers (for the current filter) that you
want to forward to the remote host
Instructions: To specify a range of event numbers that you want to use in the filter, type
the lower number of the range in this field. You then type the upper
number of the range in the Log Evt Upper Bound parameter.
The values you type for lower and upper bound are included in the range.
For example, if you specify a lower bound of 2 and an upper bound of 7,
syslog forwards all messages that are of event codes 2 through 7,
inclusive. The syslog facility ignores all other event messages.
To filter a specific event code, type the event code in this parameter. Be
sure to type the same code in the Log Evt Upper Bound parameter. For
example, to forward only the log messages that have an event code of 10,
type 10 in this field and in the Log Evt Upper Bound parameter.
If you do not want to filter by event code, accept the default, 0. Be sure to
accept the default in the Log Evt Upper Bound parameter.
If you use the wildcard filter entry, 255, the syslog facility ignores this
parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.7