Technical data
Site Manager Parameters
117347-A Rev. A B-21
Parameter: Ping Type of Service
Default: NORMAL
Options: NORMAL
| PRIORITY | IMMEDIATE | FLASH | FLASH_OVERRIDE
| CRITIC_ECP | INTERNETWORK_CONTROL
| NETWORK_CONTROL
Function: Specifies the quality of service (service precedence) for handling the
ICMP packet.
Instructions: Accept the default, NORMAL, for routine service, or choose one of the
other types of service. Refer to an IP programmer’s manual for
information about the different types of services.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.13.1.1.14
Parameter: Num Hist Buckets Requested
Default: 1
Options: 1 to 60
Function: If the ping is on a timer (that is, if you set the Timer parameter to a value
other than 0), this parameter specifies the number of entries that you want
to store in the Ping History table. In other words, you can save
information about each ping request sent on the expiration of a timer. (If
the ping is not on a timer, the ping generates only one entry in the history
table.)
Instructions: Enter a number from 1 to 60 to specify the number of instances of the
ping you want to save information about in the Ping History table.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.13.1.1.15