Technical data

Configuring and Managing Routers with Site Manager
11-8 117347-A Rev. A
3. In the Timeout field, type the number of seconds after which each ping
times out.
If the router receives a response to a ping after it times out, it does not send an
“alive” message to Site Manager.
4. In the Retries field, type the number of successive times the router should
repeat the ping.
The router does not wait for the timeout before sending the next ping.
5. Click on Ping.
IPX Ping Responses
Site Manager displays one of the following messages when you issue an IPX ping.
(If you enter a value other than 0 for Retries, Site Manager displays one of the
following messages for the default ping, plus one for each additional ping.)
A target address “is unreachable” message appears if the router cannot find
the specified network address in its table of IPX networks, for example:
IPX ping: 0xAB12.CD1234 is unreachable
An “alive” message appears if the router receives an IPX reply packet from
the target device within the timeout period, for example:
IPX ping: 0xAB12.CD1234 is alive
A “does not respond” message appears if the IPX address of the target device
is resolved, but the router does not receive an IPX reply packet from the target
device within the timeout period, for example:
IPX ping: 0xAB12.CD1234 does not respond
An “invalid parameter specified” message appears if the network or host
address is all 0s, all Fs, or not a valid IPX address, for example:
IPX ping: invalid parameter specified
A “resource error” message appears if the router cannot allocate a buffer for
the request because no buffers are available, for example:
IPX ping: resource error