Monitoring Trap and Event Messages
117347-A Rev. A 7-9
5.
Choose File > Save to save the configuration file.
Refer to Chapter 3 for more instructions on saving configuration files.
Specifying Trap Messages by Protocol Entity and Event Severity
If you configure an SNMP manager’s trap type to specific, you instruct the SNMP
agent to send trap messages based on the protocol entity and event severity level
that you specify. You must specify both criteria. For example, if you select IP as
the entity and Fault as the event severity, you receive only IP fault messages. If
you want messages for another entity, you must specify a separate entry.
To set up specific trap messages:
1. In the Configuration Manager window, choose Protocols > IP > SNMP >
Trap Configuration > Interfaces.
The Trap Configuration window opens (Figure
7-6).
Figure 7-6. Trap Configuration Window
2.
Select the appropriate slot by clicking in the Slot field.
3. Select an entity from the Available Entities list.