Appendix B Connecting to a –48 V DC Power Source
This appendix provides the relevant installation and reference information necessary for the installation
of the power cord for the BayStack Model 107 −48 Volt DC hub and the BayStack Model 107 −48 Volt
DC hub.
This appendix provides the following information about the 100-series hub:
• Cable requirements
• Safety considerations
• Attaching the ground wire
• Attaching the terminal leads
• Troubleshooting
Cable Requirements for Connection to the DC Hub
Bay Networks does not supply the cables for connecting the −48 V DC hub to the DC input power
source. This allows you to select 14-22 AWG Listed copper wire cable that complies with the electrical
code of the country where you intend to use the DC power supply.
In addition, Bay Networks recommends that you use the following crimp lug terminals:
CAUTION: This appendix contains important safety and configuration information you must
know before adding BayStack 10BASE-T hubs to your network.
7065
Redundant
Power
+
–
A six-gauge wire screw terminal (such as Panduit
part number LCA6-10F-L) to connect to the sys-
tem ground, and a #10-32×1/2 screw to connect
the terminal to the 100-series hub.