Instruction manual
Using the Console Interface
893-00992-A 3-45
The Software Download screen contains the fields listed in Table 3-15.
LED Indications During the Download Process
The software download feature is an automated process that, once initiated, runs
to completion without user intervention. The download process erases the
contents of flash memory and replaces it with a new image. Because the download
process erases the contents of flash memory, it is important that the download
process is not interrupted once it is initiated. After the software download process
is complete, the switch is automatically reset and the new software image initiates
self-test. The self-test results are briefly displayed in the BayStack 350T Self-Test
screen, followed by the CI screens.
During the download process, the BayStack 350T switch is nonfunctional. You
can monitor the progress of the software download process by observing the
BayStack 350T LED indicators.
Table 3-15. Software Download screen fields
Field Description
Image
Filename:
The software image load file name
Default Value: Zero-length string
Range: An ASCII string of up to 30 printable characters
TFTP Server IP
Address:
The IP address of your TFTP load host
Default Value: 0.0.0.0 (no IP address assigned)
Range: Four-octet decimal IP address notation, where each octet of the
address is represented as a decimal value, separated by a decimal
point
Start TFTP
Load of New
Image:
This field prompts the user to choose Yes to download the switch software image
(default is No).
Use the space bar to toggle the selection to Yes.
Press [Return] to initiate the software download process.
Note: The software download process can take up to 60 seconds to complete (or more
if the load host path or network levels are congested).
To ensure that the download process is completed without interruption, do not power
down the switch for approximately 10 minutes.
Default Value: No
Range: Yes, No
BOOK.MKR Page 45 Tuesday, March 4, 1997 7:24 PM