Technical data
Using Technician Interface Software
2-8
303561-A Rev 00
Parameter: Port Slot
Attribute Name: wfSerialPortSlot
Attribute Number: 6
Default: None
Options: Set by the system
Function: The slot on which the login session for the console port is running. The
system sets this number.
Instructions: You cannot change this parameter.
Command:
get wfSerialPortEntry.6.
<port_no.>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.11.1.1.6
Parameter: Port Type
Attribute Name: wfSerialPortType
Attribute Number: 7
Default: 1 (Technician Interface)
Options: 1 (Technician Interface)
|
2 (Printer)
Function: Configures the port for either Technician Interface (Console or Modem)
or Printer. (The Printer option is not supported at this time.)
Instructions: Set according to your console requirements.
Command:
set wfSerialPortEntry.7.
<port_no.> <option>