Technical data
Using Technician Interface Software
C-44
303561-A Rev 00
Parameter: Slot Upper Bound
Attribute Name: wfSyslogEntFltrSlotUppBnd
Attribute Number: 11
Default: 0
Range: 0 to 14
Function: Along with the Slot Lower Bound, this parameter specifies a slot number
or range of slot numbers. Syslog forwards to the remote host associated
with this filter messages logged only on the slots you specified. (Consider
the location of each router in an ASN chassis as a numbered slot.)
Instructions: To specify a range of slots, set the value of this parameter to the high
number in the range. Also set the value of wfSyslogEntFltrSlotLowBnd
(Slot Lower Bound) to the low number of the range.
Any range you specify includes the values for the lower and upper bound
parameters. For example, if you specify a lower bound of 1 and an upper
bound of 4, Syslog forwards all event messages logged on slots 1 to 4.
Syslog ignores all other event messages.
To filter events for a specific slot, set the value of
wfSyslogEntFltrSlotLowBnd to the desired slot number. Set the value of
wfSyslogEntFltrSlotUppBnd to the same number. For example, to
forward only event messages logged on slot 2, set the value of
wfSyslogEntFltrSlotLowBnd and wfSyslogEntFltrSlotUppBnd to 2.
If you do not want to filter messages by slot number(s), accept the lower
and upper bound default values of 0.
Command:
set
wfSyslogEntFltrEntry.wfSyslogEntFltr
SlotUppBnd.
<host_IP_address>
.
<entity_code>
.
<filter_index>
<0 - 14>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.11