Technical data

Using Syslog Messaging to Monitor Router Events
303561-A Rev 00
C-43
Parameter: Slot Lower Bound
Attribute Name: wfSyslogEntFltrSlotLowBnd
Attribute Number: 10
Default: 0
Range: 0 to 14
Function: Along with the Slot Upper Bound, this parameter specifies a slot number
or range of slot numbers. Syslog forwards to the remote host associated
with this filter messages logged only on the slots you specified. (Consider
the location of each router in an ASN chassis as a numbered slot.)
Instructions: To specify a range of slots, set the value of this parameter to the low
number of the range. Also set the value of wfSyslogEntFltrSlotUppBnd
(Slot Upper Bound) to the higher number of the range.
Any range you specify includes the values for the lower and upper bound
parameters. For example, if you specify a lower bound of 1 and an upper
bound of 4, Syslog forwards all event messages logged on slots 1 to 4.
Syslog ignores all other event messages.
To filter events for a specific slot, set the value of
wfSyslogEntFltrSlotLowBnd to the desired slot number. Set the value of
wfSyslogEntFltrSlotUppBnd to the same number. For example, to
forward only event messages logged on slot 2, enter 2 as the value of
wfSyslogEntFltrSlotLowBnd and as the value of
wfSyslogEntFltrSlotUppBnd.
If you do not want to filter messages by slot numbers, accept the lower
and upper bound default values of 0.
Command:
set
wfSyslogEntFltrEntry.wfSyslogEntFltrSlotLowBnd
.
<host_IP_address>
.
<entity_code>
.
<filter_index>
<0 - 14>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.10