Technical data

Using Technician Interface Software
C-20
303561-A Rev 00
3.
Set entity filter attributes, as follows:
a.
To define by event number(s) the event messages you want Syslog to
select and forward to a specific remote host:
$: set wfSyslogEntFltrEntry.wfSyslogEntFltrLogEvtLowBnd.
<host_IP_address>.<entity_code>.<filter_index>
<0 - 255>
$: set wfSyslogEntFltrEntry.wfSyslogEntFltrLogEvtUppBnd.
<host_IP_address>.<entity_code>.<filter_index>
<0 - 255>
$: commit
If you do not want to define filtering by event number(s), accept the
default values for event number lower bound (0) and upper bound (255).
Then go to step 2b. Accepting these default values causes Syslog to use
only the severity and slot mask criteria for selecting and forwarding
messages.
b.
Define a severity mask
only
if you did not already define an event
number (or event number range). If you defined an event number or
number range, Syslog ignores any severity mask for this filter.
To define by severity levels the event messages you want Syslog to select
and forward to a specific remote host, enter the following:
$: set wfSyslogEntFltrEntry.wfSyslogEntFltrSevMask.
<host_IP_address>.<entity_code>.<filter_index>
<fwitd>”
$: commit
c.
To also define by slot number(s) the event messages you want Syslog
to select and forward to a specific remote host, enter the following:
$: set wfSyslogEntFltrEntry.wfSyslogEntFltrSlotLowBnd.
<host_IP_address>.<entity_code>.<filter_index>
<0 - 14>
$: set wfSyslogEntFltrEntry.wfSyslogEntFltrSlotLowUpp.
<host_IP_address>.<entity_code>.<filter_index>
<0 - 14>
$: commit
Note:
Although the valid range for the slot lower and upper boundaries is 0 to
14, specify only values within the range of actual slot numbers for the router
model you are configuring. Otherwise, the filter will not transition to an active
state.