Technical data
Using Technician Interface Software
8-42
303561-A Rev 00
If you need more contiguous free space for the image:
• Delete unnecessary or obsolete files.
• Compact the contents of the flash card.
2.
Transfer the PROM image files (for example,
freboot.exe
and
frediag.exe
)
to the flash card.
From the Technician Interface, use the
tftp command. (See “In-Band File
Transfers” in Chapter 4 if you need more information.)
3.
Establish a Technician Interface session with the router.
See Chapter 1 if you need more information about how to open a Technician
Interface session with the router.
4.
To update a boot PROM, enter:
prom -w
<volume_no.>
:
<Boot_PROM_source_file>
<slot_ID >
For example:
prom -w 2:freboot.exe 3
5.
To update a diagnostics PROM, enter:
prom -w
<volume_no.> <Diag_PROM_source_file>
<slot_ID >
For example, to upgrade the diagnostics PROMs in slots 2 through 5, enter:
prom -w 2:frediag.exe 2-5
More examples of command lines appear at the end of this section.
Note:
Once you enter the
prom
command
,
it must run to completion. The
control-c (abort) command is disabled for the duration of the
prom
command
execution to allow it to run to completion. Upgrading takes from 2 to 10
minutes per PROM. Verifying takes up to 2 minutes per PROM.
Caution:
When upgrading PROMs with new software, upgrade all slots that
contain FRE modules to avoid a mismatch of software.