Technical data
Using Technician Interface Software
8-32
303561-A Rev 00
Examples:
Turning Off the DIAG Indicator LED
The DIAG LED lights during diagnostics and goes out after diagnostics have
determined that the processor module and its associated link module are
functional. If they are not functional, the DIAG LED on the front panel and LED 8
on the FRE processor module daughterboard remain on. If this occurs, make sure
the modules are seated properly in the router and issue the
diags
command again.
Call your Bay Networks Technical Solutions Center if the DIAG LED does not go
out.
If you hot-swap a link module, the diagnostics do not automatically run and the
Fail LED on that module remains on. In this case, you can enter the following
command to switch off the Fail LED:
diags -l
<slot_number>
Displaying the Software Version
Enter
stamp
to display the current software version and the date and time it was
created.
diags -on
[
<slot_id>
]
The ARN executes all power-up diagnostics at
subsequent restarts.
diags -off
[
<slot_id>
]
The ARN skips power-up diagnostics at subsequent
restarts.
diags
The ARN restarts immediately and executes complete
diagnostics.
Note:
If you do not specify a slot number, the
diags
command switches off
the Fail LED on all slots.