Technical data
Using Technician Interface Software
8-28
303561-A Rev 00
If you choose N (no), the system terminates shutdown and displays the following
message on the console device:
Shutdown aborted.
Upon issuing this message, the system performs the reset operation.
If you choose Y, the system continues the shutdown attempt. We recommend that
you terminate this procedure after no more than one additional shutdown attempt.
Running Diagnostics
The
diags
command cold-starts one or more specified slots or the entire system.
The cold start consists of CPU, backbone, and link diagnostics, and a reboot. If
you do not enter a slot number, the system tests and reboots all slots.
Enter the following to run diagnostics on the entire system:
diags
The system returns the following message:
Perform diags on all slots? (y/n)
If you still want to run diagnostics on all slots, enter y (yes). Entering n (no)
terminates the command.
Enter the
diags
command with one of the following parameters to run diagnostics
and reboot one or more ILIs:
diags
[
<slot_no.>
]
diags
[
<slot_no.>
-
<slot_no.>
]
diags
[
<slot_no.>
,
<slot_no.>
,
. . .
,
]