Technical data
Installing and Operating BayStack ARN/DC Routers
1-26
116273-B Rev 00
Connecting a Terminal Console
You need the following items in the ARN/DC console/modem cable kit (Order
No. 110310) to connect a terminal console:
• Serial console/modem cable with 9-pin receptacle to 25-pin plug connectors
(Order No. 110307)
• Null modem crossover adapter with two 25-pin receptacle connectors
(Order No. 110308)
Once you have the appropriate equipment, complete the following steps:
1.
Turn on and configure the terminal console using the parameters in
Table 1 -7
and the instructions in the terminal documentation.
2.
Turn off the terminal.
3.
Insert the 9-pin receptacle end of the console/modem cable into the
back-panel Console interface connector (refer to Figure 1-15 on page
1-22).
4.
Attach one end of the null modem crossover adapter to the cable’s 25-pin
plug connector, then tighten the screws (refer to Figure 1-16 on page
1-22).
5.
Attach the other end of the null modem crossover adapter to the terminal
interface, often labeled Host.
Table 1-7. Console Parameters
Parameter Value
Baud rate 9600
Data bits 8
Stop bits 1
Parity None