Technical data
893-01047-A 3-1
Chapter 3
Applications and Default Configuration
This chapter provides connection instructions for typical ATMSpeed/155
applications. The chapter also describes the factory-set default configuration for
the ATMSpeed/155 module.
ATMSpeed/155 Port Applications
You can connect the ATMSpeed/155 module for optimal LAN performance. This
section provides instructions for the following types of ATM connections:
• Connecting Centillion 100 switches directly
• Connecting Centillion 100 switches through an intermediate ATM switch
• Connecting an ATM LAN emulation station to a Centillion 100 switch
Connecting Centillion 100 Switches Directly
To connect two Centillion 100 switches directly, follow these steps:
1. Configure each ATMSpeed/155 module port.
To configure ATM ports, refer to Using SpeedView 2.1 for Windows. Both
switches must have the same kind of virtual port configured.
2. Connect one end of the fiber cable to the first switch.
Note that the SC connector of the fiber cable is keyed.
3. Connect the other end of the fiber cable to the other switch.
The In Service LED for the ATM port turns on when the switch recognizes the
physical connection. You can view the LED on the switch itself or through the
SpeedView application by selecting the Switch menu and choosing View.