Operating instructions
ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE
Fire Detection - Addressable
6000/MCP FAST
TM
Addressable Manual Call Point - Key
operated test facility, a loop short circuit isolator
is incorporated.
6000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Single
pipe air sampling unit for air speeds from 0.5 to 20m
per sec. supplied with 6000PLUS/BASE suitable for
use with 6000PLUS/OP FAST
TM
interactive optical
smoke sensor.
6000/FIREBEAM FAST
TM
Addressable Loop Powered Beam
Detector - Combined transmitter/receiver unit and
separate low level controller. With a beam range
of 5-100 metres.
6000/LED FAST
TM
Addressable Loop Powered High Intensity
Flashing Beacon - The 6000/LED has 18 high
intensity LEDs, and due to the low current design,
is addressable and loop powered, utilising the
Protec Algo-Tec
TM
6000 Protocol.
6000/FIU Flush Mounted Short Circuit Isolator Unit - To
isolate a short circuit fault on either the incoming
or outgoing loop cables. Suitable for a 30mm deep
electrical mounting box.
6000/LPZA FAST
TM
Addressable Flush Mounted Loop
Powered Zone Alarm Interface Unit - With a
monitored detection circuit suitable for use
with Protec 3000 series detection devices. Line
continuity maintained. Monitored alarm output
circuit rated at 24Vdc 50mA max. Suitable for a
45mm deep electrical mounting box. A loop short
circuit isolator is included.
6000/ZAI FAST
TM
Addressable Flush Mounted Zone Alarm
Interface Unit - With a monitored detection circuit
suitable for use with Protec 3000 series detection
devices. Line continuity maintained. Monitored
alarm output circuit rated at 24V dc 1A max.
Suitable for a 45mm deep electrical mounting box.
A loop short circuit isolator is included.
Multi-way Input/Output Interfaces - A range of 16 way input/
output interfaces are available with monitored
alarm outputs or clean changeover contacts. All
interfaces are FAST
TM
addressable.
Table detailing the loop standby and alarm load for typical
Algo-tec™ 6000 devices.
Note: The following Loop Parameters should be observed
1) The total number of addressable devices should not exceed 191 per loop.
2) Add 20mA to total loop alarm load to allow for fire indicator LED’s on devices
3) The total loop alarm load should not exceed 600mA per loop.
* Auxiliary 24V dc supply required.
Guide to loop cable conductor sizing for the Protec 6300 system.
Loop Length (Metres)
Loop Length (Metres)
Total
Loop
Load
in
Alarm
(mA)
50
100
150
200
250
300
350
400
450
500
550
600
50
100
150
200
250
300
350
400
450
500
550
600
1000
1050
1100
1150
1200
1250 1300
1350
1400 1450
1500
500 550 600650 700750 800850 900950 1000
Total
Loop
Load
in
Alarm
(mA)
n/a
n/a
n/an/an/a
The conductor size required is as follows
1.0mm² Conductor required.
1.5mm² Conductor required.
2.5mm² Conductor required.
Maximum loop resistance 16 ohms per conductor
6000/SSR FAST
TM
Addressable Loop Powered High Output
Electronic Sounder - utilises a Piezo driver unit
to enable high sound output and very low current
consumption.
The conductor size required as follows
1.0mm
2
Conductor required
1.5mm
2
Conductor required
2.5mm
2
Conductor required
MAXIMUM LOOP RESISTANCE 16 OHMS PER CONDUCTOR
6000/MICCO FAST
TM
Addressable Flush Mounted Loop Powered
Monitored Input, Clean Contact Output Interface
Unit - With a monitored input circuit suitable for
use with simple switch devices and the output is
a clean changeover contact 5amp rated at 240V
ac. A link can be cut to provide a 7-second delay
to the input. Suitable for a 45mm deep electrical
mounting box. A loop short circuit isolator is incorporated.
6000/SSR/LED FAST
TM
Addressable Loop Powered High Output
Electronic Sounder with LED Beacon - a low
current loop powered addressable device. With
typical sound output of 100dB(A) at 1m, the tone
and volume options are selectable by the control
panel.
6000PLUS/TSR2 FAST
TM
Addressable Loop Powered Talking
Sounder - The 6000PLUS/TSR2 voice enhanced
talking sounder is available with seven voice
messages plus ‘bell’ sound in addition to the three
fire alarm tones compatible with the Protec range
of electronic sounders.
6000PLUS/TSR2/LED FAST
TM
Addressable Loop Powered Talking
Sounder with LED Beacon - the Protec Algo-
Tec™
6000PLUS/TSR2/LED is equipped with an
integrated voice enhanced sounder and high
intensity flashing beacon array.
Product Description
Number of
Addresses
Loop
Standby
Load mA
Loop Alarm
Load mA
6000/MCP Manual Call Point 1 0.5 3.4
6000/FIREBEAM Loop Beam 1 3.65 7
6000PLUS/HT Heat Sensor 1 0.2 0.2
6000PLUS/HT/S Heat Sensor c/w Sounder 1 0.4 5.4
6000PLUS/OPHT Optical Smoke and Heat Sensor 1 0.2 0.2
6000PLUS/OPHT/S
Optical Smoke and Heat Sensor c/w
Sounder
1 0.4 5.4
6000PLUS/OPHT/SL
Optical Smoke and Heat Sensor c/w
Sounder and Beacon
1 0.4 10.4
6000PLUS/OPHT/TSL
Optical Smoke and Heat Sensor c/w
Talking Sounder and Beacon
1 0.4 13.4
6000PLUS/OPHTCO Optical Smoke, Heat, and CO Sensor 1 0.45 0.45
6000PLUS/OPHTCO/S
Optical Smoke, Heat, and CO Sensor
c/w Sounder
1 0.45 5.45
6000/LED Loop Beacon 1 0.5 5.5
6000/SSR Loop Sounder 1 0.7 5.7
6000/SSR/LED Loop Sounder Beacon 1 0.7 10.7
6000/ZAI* Zone Alarm Interface 1 2 4
6000/MICCO Monitored Input CC Output 1 0.55 5