Operating instructions

LOOP 1
LOOP 2
Plant shutdown
interface 6000/MICCO
Heavy duty plant
shutdown
signal (Rated at 240V 5A)
Single 2 wire loop cable
230V ac Supply
4 Programmable
monitored alarm outputs
2 Auxiliary fire C/O contacts
Fault C/O contacts
24V Aux. Output
Bomb alert/class change input
24V supply (4C)
Power supply unit
BC1/2.8
Monitored fire station output
}
}
230V
6000/LPZA
Loop powered
zone alarm
interface
Optional RS232 port:
Hercules colour graphics
pager or BMS interface
Zone circuit
Alarm circuit
6300 Loop repeater
LOOP 2
Plant shutdown output
(Rated at 240V 5A)
Sprinkler delay
interface 6000/MICCO
6000/ZAI
Zone alarm
interface
Zone circuit
Alarm circuit
EOL
EOL
EOL
4 Core serial
communications link
(up to 4 Repeaters)
2 Core RS485 Network using 6300
Netcard in each panel/repeater
(up to 32 panels)
6300 Serial
Communication Link
6300 Secure Network
NOTE: The Serial Communication Link cannot be used if the secure network (option 2) is chosen.
Option 1
OR
Option 2
EOL
ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE
Fire Detection - Addressable
Protec Fire Detection plc
Protec Algo-Tec
TM
6300
INTERACTIVE DIGITAL ADDRESSABLE
FIRE CONTROL SYSTEM
Loop Devices
The Protec Algo-Tec
6000PLUS protocol utilises FAST
addressing
(Firmware Addressed Secure Technology). Every FAST
device is
manufactured with a unique serial number.
FAST
addressing ELIMINATES troublesome and time consuming
address cards and DIL switching whilst being far more secure than
“soft addressing”.
The Protec Algo-Tec™ 6000PLUS sensor range has been developed
to incorporate advanced fire sensing technology, electronic
sounders, high intensity LED warning beacons and speech enhanced
talking sounder capability, all integrated within the sensor head and
powered from the loop.
Typical Sensor Variants
6000PLUS/OPHT/S = c/w Sounder
6000PLUS/OPHT/L = c/w LED Beacon
6000PLUS/OPHT/SL = c/w Sounder and LED Beacon
6000PLUS/OPHT/TS = c/w Talking Sounder
6000PLUS/OPHT/TSL = c/w Talking Sounder and LED Beacon
Heat Sensor
Optical Smoke and Heat Sensor
Optical Smoke, Heat and CO Sensor
Duct Probe Unit c/w Smoke Sensor
Manual Call Point
Beam Detector
Loop Powered Zone Alarm Interface
KEY:
Zone Alarm Interface
Monitored Input CC Output Interface
Electronic Sounder
Flashing Beacon
Talking Sounder with LED Beacon
6300 Loop LCD Display
6300 Zonel Mimic
6300 Repeat Panel
6000PLUS/HT FAST
TM
Interactive Heat Sensor - Interactive
addressable heat sensor with low thermal mass
thermister, giving fast response to temperature
increases. Other Heat Sensor variants include:
6000PLUS/HT/S, 6000PLUS/HT/SL
6000PLUS/HT/TSL
6000PLUS/OP FAST
TM
Interactive Optical Smoke Sensor -
Interactive addressable high performance optical
smoke sensor provide efficient reliable detection
using the light scatter sensing principle with
rapid response to a fire signal. Other Optical
Sensor variants include: 6000PLUS/OP/S
6000PLUS/OPHT FAST
TM
Interactive Optical Heat Sensor -
Interactive addressable high performance optical
smoke and heat multi-sensor. Other Optical Heat
Sensor variants include:
6000PLUS/OPHT/S, 6000PLUS/OPHT/L,
6000PLUS/OPHT/SL, 6000PLUS/OPHT/TS,
6000PLUS/OPHT/TSL
6000PLUS/OPHTCO FAST
TM
Interactive Optical Heat CO Sensor -
Interactive addressable high performance optical
smoke heat and carbon monoxide multi-sensor.
Other Optical Heat Sensor variants include:
6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/L,
6000PLUS/OPHTCO/SL, 6000PLUS/OPHTCO/TSL
6000PLUS/BASE Low Profile Common Mounting Base -
Compatible with the above range of Algo-Tec
TM
6000PLUS Sensors.
6000PLUS/FFBASE Fast Fixed Base - Fast fixed recessed base is
designed to recess the sensor into a false ceiling
to give a lower profile view of the sensor.
6300/LOOP/LCD Repeater - Connected directly to the local data
loop and takes up just one address. The 1 x
40 character LCD Display provides clear text
location of fire and fault events.