Operating instructions
LOOP 1 
LOOP 2
Plant shutdown
interface 6000/MICCO
 Heavy duty plant 
shutdown
 signal (Rated at 240V 5A) 
Single 2 wire loop cable
230V ac Supply
4 Programmable
monitored alarm outputs
2 Auxiliary fire C/O contacts
Fault C/O contacts
24V Aux. Output
Bomb alert/class change input
24V supply (4C)
Power supply unit
BC1/2.8
Monitored fire station output
}
}
230V
6000/LPZA
Loop powered 
zone alarm
interface
Optional RS232 port:
Hercules colour graphics
pager or BMS interface
Zone circuit
Alarm circuit
6300 Loop repeater
LOOP 2
Plant shutdown output 
(Rated at 240V 5A)
Sprinkler delay
interface 6000/MICCO
6000/ZAI
Zone alarm
interface
Zone circuit
Alarm circuit
EOL
EOL
EOL
4 Core serial
communications link
(up to 4 Repeaters)
2 Core RS485 Network using 6300 
Netcard in each panel/repeater
(up to 32 panels)
6300 Serial
Communication Link
6300 Secure Network
NOTE: The Serial Communication Link cannot be used if the secure network (option 2) is chosen.
Option 1
OR
Option 2
EOL
ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE
Fire Detection - Addressable
Protec Fire Detection plc
Protec Algo-Tec
TM
 6300
INTERACTIVE DIGITAL ADDRESSABLE
FIRE CONTROL SYSTEM
Loop Devices
The Protec Algo-Tec
™
 6000PLUS protocol utilises FAST
™
 addressing 
(Firmware Addressed Secure Technology). Every FAST
™
 device is 
manufactured with a unique serial number.
FAST
™
 addressing ELIMINATES troublesome and time consuming 
address cards and DIL switching whilst being far more secure than 
“soft addressing”.
The Protec Algo-Tec™ 6000PLUS sensor range has been developed 
to incorporate advanced fire sensing technology, electronic 
sounders, high intensity LED warning beacons and speech enhanced 
talking sounder capability, all integrated within the sensor head and 
powered from the loop. 
Typical Sensor Variants
6000PLUS/OPHT/S = c/w Sounder
6000PLUS/OPHT/L = c/w LED Beacon
6000PLUS/OPHT/SL = c/w Sounder and LED Beacon
6000PLUS/OPHT/TS = c/w Talking Sounder
6000PLUS/OPHT/TSL = c/w Talking Sounder and LED Beacon
Heat Sensor
Optical Smoke and Heat Sensor
Optical Smoke, Heat and CO Sensor
Duct Probe Unit c/w Smoke Sensor
Manual Call Point
Beam Detector
Loop Powered Zone Alarm Interface
KEY:
Zone Alarm Interface
Monitored Input CC Output Interface
Electronic Sounder
Flashing Beacon
Talking Sounder with LED Beacon
6300 Loop LCD Display
6300 Zonel Mimic
6300 Repeat Panel
6000PLUS/HT    FAST
TM
  Interactive Heat Sensor - Interactive 
addressable heat sensor with low thermal mass 
thermister, giving fast response to temperature 
increases. Other Heat Sensor variants include:
6000PLUS/HT/S, 6000PLUS/HT/SL
6000PLUS/HT/TSL
6000PLUS/OP    FAST
TM
  Interactive Optical Smoke Sensor - 
Interactive addressable high performance optical 
smoke sensor provide efficient reliable detection 
using the light scatter sensing principle with 
rapid response to a fire signal. Other Optical 
Sensor variants include: 6000PLUS/OP/S
6000PLUS/OPHT  FAST
TM
  Interactive Optical Heat Sensor - 
Interactive addressable high performance optical 
smoke and heat multi-sensor. Other Optical Heat 
Sensor variants include:
6000PLUS/OPHT/S, 6000PLUS/OPHT/L,
6000PLUS/OPHT/SL, 6000PLUS/OPHT/TS, 
6000PLUS/OPHT/TSL
6000PLUS/OPHTCO FAST
TM
  Interactive Optical Heat CO Sensor - 
Interactive addressable high performance optical 
smoke heat and carbon monoxide multi-sensor. 
Other Optical Heat Sensor variants include: 
6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/L,
6000PLUS/OPHTCO/SL, 6000PLUS/OPHTCO/TSL
6000PLUS/BASE  Low Profile Common Mounting Base - 
Compatible with the above range of Algo-Tec
TM
6000PLUS Sensors.
6000PLUS/FFBASE  Fast Fixed Base - Fast fixed recessed base is 
designed to recess the sensor into a false ceiling 
to give a lower profile view of the sensor.
6300/LOOP/LCD Repeater - Connected directly to the local data 
loop and takes up just one address. The 1 x 
40 character LCD Display provides clear text 
location of fire and fault events.
Protec
Protec Fire Detection plc