Operating instructions
ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE
Fire Detection - Addressable
FEATURES & BENEFITS
• Cost Effective -
High specification interactive digital
addressable fire detection and alarm system,
providing a cost effective solution for small, medium
and large sized buildings and sites.
• Design Flexibility -
Up to 32 control panels, repeats and illuminated zonal
mimics can be networked enabling system design
and expansion to be easily achieved to suit the site
for economic wiring and operational convenience.
• Secure Network -
Wired as a loop, the network’s dual channel RS485
link ensures that no single fault will affect the system.
• Easy to Install -
An extensive range comprising Loop Powered Alarm
Sounders, Beacons, Interfaces, Manual Call Points
and Sensors can all be connected to the nearest
control panel using a single 2-core cable for each
of the high capacity Loops (up to 4), accommodating
up to 191 devices per Loop, 512 maximum per panel.
• Reduced False Alarms -
The Protec Algo-Tec
TM
6000 interactive fire sensors
utilise advanced discriminating algorithms for
maximum reliability and immunity to false alarms.
• Enhanced Performance -
The Protec Algo-Tec
TM
6000 sensors learn from
their environment, applying interactive decision
making algorithms to provide stability, threshold
compensation and optimised performance.
• Secure Detection Loops -
Many Protec Algo-Tec
TM
6000 devices incorporate
built-in short circuit isolator units. These can be
located as required.
• Easy to Address -
‘FAST’ addressing (Firmware Addressed Secure
Technology) ELIMINATES troublesome and time
consuming setting of address cards and DIL switches.
• Devices Display Address Number -
‘RVAV’ Remote Visual Address Verification.
Confirmation of the correct location of each device
can be easily identified, using the devices in-built LED
to indicate the device address number.
• On Site Flexibility -
Configuration of all system functions is fully site
programmable.
• Reduced Maintenance Costs -
Early indication and reporting of sensors approaching
contamination level reduce false alarms and enable
dirty sensors to be cleaned or replaced.
• Optional RS232 Port -
Typically used to connect to a colour graphics
system, pager system or BMS interface. Allows PC
connection for backup and programming.
• Designed to EN 54-2 & 4
BUILDING 2
BUILDING 1
BUILDING 3
BUILDING
4
BUILDING 5A
BUILDING
5B
230V ac
230V ac
230V ac
230V ac
230V ac
Up to 32 panels on a network
2 Core RS485
Secure Network
24V dc From Panel or P.S.U.
Colour Graphics System
Typical 6300 Network System