Fire Detection - Addressable Protec Protec Fire Detection plc Protec Algo-TecTM 6300 Interactive Digital Addressable Fire Control System A D D R ESS IN G S A F E T Y SYST E M S W I T H I NT E L L I G E N CE
Fire Detection - Addressable Protec P r ot ecFire Fir e Detection De tecti on pl cplc Protec Protec Algo-TecTM 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM The Protec Algo-Tec™ 6300 Interactive Digital Addressable System unwrapped: The Protec Algo-TecTM 6000 protocol developed by Protec’s in-house Research and Development team is utilised by the Protec Algo-TecTM 6300 interactive digital addressable fire control systems.
Typical 6300 Network System • Cost Effective High specification interactive digital addressable fire detection and alarm system, providing a cost effective solution for small, medium and large sized buildings and sites. • Design Flexibility Up to 32 control panels, repeats and illuminated zonal mimics can be networked enabling system design and expansion to be easily achieved to suit the site for economic wiring and operational convenience.
Fire Detection - Addressable Protec P r ot ecFire Fir e Detection De tecti on pl cplc Protec Protec Algo-TecTM 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM CONTROLS & DISPLAYS System Features The Protec Algo-TecTM 6300 is an interactive digital addressable fire detection and alarm system ideally suited for small , medium & large sized buildings such as nursing homes, hotels and offices. The control panel is designed and manufactured by Protec to comply with EN 54-2 & 4.
Liquid Crystal Display The 80, large character liquid crystal display will under normal quiescent conditions display the current date and time with the option to also display a 40-character user’s message such as site name. In an alarm or fault condition the LCD will display the device loop, address and zone number and up to 40 characters of user definable location text, programmable on site using Protec 6300/WINTEXT windows based software.
Fire Detection - Addressable Protec Plant shutdown interface 6000/MICCO Heavy duty plant shutdown signal (Rated at 240V 5A) INTERACTIVE DIGITAL ADDRESSABLE EOL Typical Sensor Variants 6000PLUS/OPHT/S = c/w Sounder 6000PLUS/OPHT/L = c/w LED Beacon 6000PLUS/OPHT/SL = c/w Sounder and LED Beacon 6000PLUS/OPHT/TS = c/w Talking Sounder 6000PLUS/OPHT/TSL = c/w Talking Sounder and LED Beacon 6000PLUS/HT FASTTM Interactive Optical Smoke Sensor Interactive addressable high performance optical smoke sensor provi
500 550 600 650 Loop Length (Metres) 700 750 800 850 900 950 FASTTM Addressable Manual Call Point - Key operated test facility, a loop short circuit isolator is incorporated. 1000 50 100 6000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Single pipe air sampling unit for air speeds from 0.5 to 20m per sec. supplied with 6000PLUS/BASE suitable for use with 6000PLUS/OP FASTTM interactive optical smoke sensor.
Fire Detection - Addressable Technical Specification 6300 Control Panel Complies with EN 54-2 & 4 Models:- 6301 - Single Loop Panel 6302 - 2 Loop Panel 6304 - 4 Loop Panel Specification:Power Supply Working Voltage Temperature Range Maximum Humidity Panel Model Standby Load (Mains Fail Condition) Alarm Load (Mains Fail Condition) Display Digital Addressable Loops Total Loop Load Zones Integral Charger Integral Battery Remote Power Supply Programmable Alarm Outputs Alarm Load Fault Monitoring Fault Out