Technical data

Table Of Contents
13
Remote Annex Quick Start for UNIX
166-024-857 Rev. A
2. Modify the following parameters in the external CSU
through its front panel:
FORMAT (FDL) = ANSI (or ATT)
CLOCK = SLAVE
DISTANCE = 133 ft.
3. Use na to enable SNMP sets, modify the PRI parameter
switch_type if it is other than 5ess (NI-2 or DMS100, for
example) and specify the distance between the Annex and
the CSU.
% na
command: annex 129.9.200.62
command: set annex allow_snmp_sets y
command: set pri switch_type dms
command: set pri dsx1_line_length 101-135
command: boot
command: quit
Setting PRI Channels Using Annex Manager
To configure Remote Annex Ports using Annex Manager:
1. Start Annex Manager:
gui_am
2. Enter the name of the Annex or its IP address and click on
.
3. Fill out the items in the window and click on
.
4. Repeat Step 3 for screen in the Setup Option Menu in the
upper right corner of the window.
Setup...
Apply