Technical data

Table Of Contents
7
Remote Annex Quick Start for Windows
166-024-858 Rev. A
Remote Annex 6300
Remote Annex 5393
1. Enter addr and answer the prompts as shown in the
example. To accept the default shown in brackets, press the
key.
monitor:: addr
Enter Internet address (hex) <uninitialized>::
192.9.200.62
Enter Subnet mask [255.0.0.0]::
Enter Broadcast address [0.0.0.0]::
Enter Preferred Load Host address [<any host>]::
192.9.200.55
Enter Preferred Dump Host address [0.0.0.0]::
Enter Preferred Load/Dump Gateway address
<uninitialized>::
Select type of IP packet encapsulation (ieee802/
ethernet) [<ethernet>]::
Load Broadcast y/n [y]::
All Annexes
2. If you have purchased a LAT key, enter the software key
provided by Bay Networks.
monitor:: lat
Enter LAT KEY: [<uninitialized>]::
Booting the Remote Annex
At the Remote Annex, enter boot at the monitor prompt:
monitor:: boot
Enter boot file name [oper.46.enet]::
Requesting boot file "oper.46.enet".
Unanswered requests shown as "?", transmission errors as "*".
Requesting boot from 192.9.200.55 via Ethernet...
Booting from 192.9.200.55
Header received OK. Received data blocks shown as "."
. . . . . . . . . . . . . . .EOF
The boot file requested in the example is for a Remote Annex 4000
or 6100. Boot files for other models are:
Remote Annex 2000 oper.56.enet
Remote Annex 6300 oper.63.enet
Return