Specifications
9031398 E3 Token Ring Modules
B-7
Configuration Views
Module Configuration View
Attachment Changes
Displays the total number of attachment changes for the module detected
since cold/warm start of the agent or since the insertion of the module.
Last Attachment Change
Displays the value of SysUpTime when the last attachment change on the
module was detected. If no change has been detected since cold/warm start of
the agent, the value is zero.
Configuration Source
Displays the source of the configuration at the last module reset. Table B-6
lists the possible values and their descriptions.
Configuration Changes
Displays the total number of configuration changes for the module detected
since the cold/warm start of the agent or since the insertion of the module.
Module Attachment Table
The Module Attachment Table, at the bottom of the Module Configuration
View, provides information on each of the attachments on the module. Double-
click any entry in this table to access the Attachment Configuration view,
described later in this chapter. A Print button allows you to output a copy of
this table to a printer or a file. This table provides the following information:
Attachment
Displays the number identifying the network attachment point on the module.
Current
Displays the current channel or segment for this attachment (for example,
Loc_1).
Table B-6. Configuration Source Values
Value Description
Other Unknown or some other value
DfltJmpr (2) Default jumpers
PrmMem (3) Permanent memory on the module
BrdCfg (4) Saved configuration on the module
Sm (5) Supervisor
SmDfltJmpr (6) SM and default jumpers
SmPrmMem (7) SM and permanent memory on the module