Specifications
Token Ring NMM Agent Events and Alarms
Event and Alarm Messages
6-16
SynOptics Series 5000
Management Module Guide
CsEvFormat/Event00010810
{d “%w- %d %m-, %Y - %T”} - RMON
rising threshold trap received from
model {m} of type {t}. AlarmVariable
{O 2}, AlarmSampleType {I 3},
AlarmValue {I 4}, and
AlarmRisingThreshold {I 5}.
No Probable Cause Message
CsEvFormat/Event00010811
{d “%w- %d %m-, %Y - %T”} - RMON
falling threshold trap received from
model {m} of type {t}. AlarmVariable
{O 2}, AlarmSampleType {I 3},
AlarmValue {I 4}, and
AlarmFallingThreshold {I 5}.
No Probable Cause Message
CsEvFormat/Event01020001
{d “%w- %d %m-, %Y - %T”} A “hot
swap” has been detected in slot {O 2}
(slot is second digit). Operational state
is {T Syn5OpTable 3}. {t} (name - {m}).
(Trap type: 0x01) - (event [{e}]
CsPCause/Prob01020001
DCE CONTACT LOST
PROBABLE CAUSES:
1) One or more DCE’s on the NMM have
lost contact.
RECOMMENDED ACTIONS:
1) Check the Device View to ensure the
DCE is on a backplane segment that has a
network feed.
2) Check the network connection to the
backplane segment that the DCE is
monitoring.
CsEvFormat/Event01020002
{d “%w- %d %m-, %Y - %T”} The
operational condition of component {O
2} is {T Syn5OpTable 3}. [component
first digit - (1) Supervisory Module (2)
Backplane (3) Module (4) Power
Supply (5) Temp Sensor (6) Fan (7)
Clock]. {t} (name - {m}). (Trap type:
0x02) - (event [{e}])
CsPCause/Prob01020002
CHASSIS PROBLEM
PROBABLE CAUSES:
1) The component or sub-component listed
in the description has a problem condition,
either warning, non-fatal, or fatal.
RECOMMENDED ACTIONS:
1) Check the component or sub-component
listed in the problem description.
Table 6-4. Token Ring NMM Agent Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause