Specifications

Ethernet NMM Agent Events and Alarms
Event and Alarm Messages
6-4
SynOptics Series 5000
Management Module Guide
CsEvFormat/Event00010811
{d “%w- %d %m-, %Y - %T”} - RMON
falling threshold trap received from model
{m} of type {t}. AlarmVariable {O 2},
AlarmSampleType {I 3}, AlarmValue {I 4},
and AlarmFallingThreshold {I 5}.
No Probable Cause Message
CsEvFormat/Event01020001
{d “%w- %d %m-, %Y - %T”} A “hot swap”
has been detected in slot {O 2} (slot is
second digit). Operational state is {T
Syn5OpTable 3}. {t} (name - {m}). (Trap
type: 0x01) - (event [{e}]
CsPCause/Prob01020001
DCE CONTACT LOST
PROBABLE CAUSES:
1) One or more DCEs on the NMM have
lost contact.
RECOMMENDED ACTIONS:
1) Check the Device View to ensure the
DCE is on a backplane segment that has
a network feed.
2) Check the network connection to the
backplane segment that the DCE is
monitoring.
CsEvFormat/Event01020002
{d “ %w- %d %m-, %Y - %T”} The
operational condition of component {O 2} is
{T Syn5OpTable 3}. [component first digit -
(1) Supervisory Module (2) Backplane (3)
Module (4) Power Supply (5) Tempt Sensor
(6) Fan (7) Clock]. {t} (name - {m}). (Trap
type: 0x02) - (event [{e}])
CsPCause/Prob01020002
CHASSIS PROBLEM
PROBABLE CAUSES:
1) The component or sub-component
listed in the description has a problem
condition, either warning, non-fatal, or
fatal.
RECOMMENDED ACTIONS:
1) Check the component or sub-
component listed in the problem
description.
Table 6-2. Ethernet NMM Agent Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message