Specifications
Token Ring DCE Management Views
DCE Management Views
5-20
SynOptics Series 5000
Management Module Guide
Token Ring Staton Control View
The Token Ring Station Control view provides detailed information on the
configuration of the selected station from the DCE Station Table. This view
allows you to update the configuration of the station using the fields provided.
The Token Ring Station Control view provides the following information:
Source Index
Displays the index of the entry in the table. This index identifies the DCE that
is the source of the information. Only those DCEs that provide the previously
described statistics are in this view.
MAC Address
Displays the MAC Address of the station.
Physical Location
Displays the physical location of the station on the ring. If unknown, the value
is four octets of zero.
Remove Station
This field provides a button, allowing you to send a Remove Station MAC
frame to the station.
Functional Address
Displays the functional address used by the station. If unknown, the value is
four octets of zero.
Update Station
Provides a button which updates the configuration information for the station.
Functional Classes
Displays the functional classes that are allowed to be active on the station. If
unknown, the value is two octets of zero.
Last Updated
Displays the value of SysUpTime when the station configuration information
was last updated completely. If the information has never been retrieved, the
value is zero. The station configuration information is updated whenever a
station is first detected on the ring.
Group Address
Displays the group address for the station. If unknown, or unassigned, the
value is zero.
Product ID
Displays a brief string describing the product specified by the vendor. If
unavailable, the value is a zero length string.
Maximum Priority
Displays the maximum priority this station is allowed to use. If unknown, the
value is two octets of zero.