Specifications
9031398 E3 DCE Management Views
5-13
Token Ring DCE Management Views
Token Ring DCE Station Table
Token Ring DCE Station Table
The Token Ring DCE Station Table view provides information related to the
stations on the ring, as well as access to more detailed views. Double-click a
row in the table to access the Station Detail view which contains two color-
coded pie charts that provide a breakdown of Isolating and Non-Isolating
Errors. The definitions of these errors are described later in this section.
To access this table, do the following:
1. Highlight the DCE icon in the Device view.
2. Select DCE Stations -> Station Table from the Icon Subviews menu.
or:
1. Highlight the DCE icon in the DCE view.
2. Select DCE Stations -> Station Table from the Icon Subviews menu.
The Token Ring DCE Station Table view provides the following buttons which
access additional views:
Accesses the DCE Station Isolating Errors Table view, described later in this
section.
Accesses the DCE Station Non-Isolating Errors Table view, described later in
Token The total number of times the DCE has detected an error on the ring
that required the transmission of a new token. A token error can be
caused by the following conditions:
• A token with non-zero priority and a monitor count bit set to 1.
• A frame and monitor count bit set to 1.
• No token or frame received within 10ms.
• The starting delimiter/token sequence had a code violation.
Frequency The total number of frequency errors detected on this DCE.
Table 5-9. Non-Isolating Errors Breakdown Pie Chart Definitions (Continued)
Statistic Definition
DCE Station Isolating Errors
DCE Station Non-Isolating Errors