9031398 E3 DCE Management Views
5-9
Token Ring DCE Management Views
Token Ring DCE Performance View
maximum of 256, up to the current value of this field. For example, if the
value of this field is 112, the station table could contain entries for 100
inactive stations, and 12 active stations.
Active Stations
Displays the number of active stations in this ring. This reflects the number of
active stations in the station information table.
Station Changes
Displays the number of add and delete events in the station information table
associated with this ring. If no changes have occurred, the value is zero.
Station Deletes
Displays the number of times stations were removed from the station
information table due to either aging out or a table overflow.
Last Deleted
Displays the value of SysUpTime when the last station was removed from the
station information table. If no stations have been removed, the value is zero.
Age Interval
Displays the amount of time used to age stations from the station information
table. If a station has had a status of inactive in the last time interval, it may
be removed from the station information table. A value of zero indicates that
no aging will occur.
Token Ring DCE Performance View
The Token Ring DCE Performance views display a Multi-Attribute Line Graph
that provides a general indication of network activity for the DCE. The
attributes displayed are pre-selected and use colors to represent different
statistics. The attributes are displayed as current values, average values, and
peak values. The peak values display the highest statistical value reached
since SPECTRUM began logging and the current time, or the time at which the
peak value was reached if one exists.
To access this view, do the following:
1. Highlight the DCE icon in the Device view.
2. Selecting DCE Performance from the Icon Subviews menu.
or:
1. Highlight the DCE icon in the DCE view.
2. Selecting DCE Performance from the Icon Subviews menu.
This view also has the following fields:
DCE
Displays the numbers identifying the position of the module and the exact DCE