Installation guide

2-29Remote Annex 4000 Hardware Installation Guide
Chapter 2 Installing the Remote Annex 4000
If all requests fail, the Remote Annex 4000 will return to the ROM
monitor (if in Test mode) or continue the auto-initializing procedure
indefinately (if in normal mode).
BOOTP
For a successful BOOTP retrieval, a bootpd must be running on a host
on the same network as the Remote Annex 4000 and must have the
appropriate information in the bootptab file. The Remote Annex
4000s BOOTP implementation adheres to rfc951, rfc1048, and
rfc1084. A sample bootptab file entry used to initialize the Remote
Annex 4000 named terminator looks like this:
In the previous example:
sm is the subnet mask.
gw is the load/dump gateway address.
vm is the Vendor Magic Cookie.
ht is host type (1=Ethernet).
ha is the Remote Annex 4000’s hardware address (Ethernet
Address).
ip is the Remote Annex 4000’s Internet Address.
remoteannexdefault:\
:sm=255.255.255.0:gw=132.245.22.66:\
:hn:vm=auto:to=-18000:
terminator:\
:ht=1:ha=00802d004879:ip=132.245.22.226:\
:tc=remoteannexdefault: