Installation guide

3-31Remote Annex 4000 Hardware Installation Guide
Chapter 3 ROM Monitor Commands
slip
The slip command defines a serial port as a Serial Line Internet
Protocol (SLIP) interface. The command automatically sets the
number of data bits to 8 for all SLIP interfaces. The number of data
bits does not include the start, stop, or parity bits.
Table 3-2 lists the
information for which the slip command prompts. The syntax is:
slip [–d] [port]
The slip –d command displays all of the current settings.
After entering the slip command, you are prompted for each
parameter. The port is the number of the serial port to be configured
with this command. If you do not enter a port number, you are
prompted for one. The slip command display looks like this:
Pressing -C interrupts the slip command; the
parameters remain unchanged until the command
completes normally.
monitor:: slip
Line number (1–16)::6
Allow SL/IP on this port? (y/n) [n]::y
Enter local endpoint address [0.0.0.0]::192.9.200.214
Local endpoint address: 192.9.200.214
Enter subnet mask [255.0.0.0]::
Constructed new subnet mask.
Enter remote endpoint address [0.0.0.0]::192.9.200.0
Remote endpoint address: 192.9.200.0
Enter remote load/dump host address [default
192.9.200.88]::
Remote load/dump host address: 192.9.200.88
Should this interface be used for memory dumps? (y/n) [y]::
Enter the baud rate [9600]::
Enter the number of stop bits (1,1.5,2) [1]::
Enter the parity (none,even,odd) [none]::
WARNING
Contro
l