Technical data
2.0 Technical Data
6
25
75
121
392
439
442
268
144144
4
107 Dia
without 
internal
fitting
117 Dia
with 
internal
fitting
Centre of
Gas Connection
8 Slots
20 x 6
Layout of Fixing Points
30, 40 and 50 models
25
75
121
392
439
442
380
196196
52
107 Dia
without 
internal
fitting
117 Dia
with 
internal
fitting
Centre of
Gas Connection
8 Slots
20 x 6
Layout of Fixing Points
60, 70 and 80 models
(4) 10
(8) 20
(16) 40
(24) 60
(12) 30
(20) 50
(28) 70
(32) 80
(36) 90
(40) 100
(44) 110
(48) 120
2 4 6 8 10121416 182022
Water Flow Rate litres / min
Pressure Drop mbar (in wg)
242628 30
(52) 130
(4) 10
(8) 20
(16) 40
(24) 60
(12) 30
(20) 50
(28) 70
(32) 80
(36) 90
(40) 100
(44) 110
(48) 120
2 4 6 8 10121416 182022
Water Flow Rate litres / min
Pressure Drop mbar (in wg)
242628 30
(52) 130
30, 40 and 50 models
60, 70 and 80 models
Templates
Hydraulic Resistance Charts
• This appliance is only intended for installation on a governed supply.
• PMS = 3 bar pressure class 2
• Max CH water pressure 3 bar
• Type C
12,
C
32, 
C
52
• Nox class 1
• Appliance category I
2H
2H - G20 - 20mbar
• Ref: 86/AU/588
• Burner Injector Sizes: 30=B12 40=B13 50=B14 60=B15 70=B30 80=B16
• This boiler is designed to operate at a maximum water temperature of 85° C.
61.3mm
Model Seasonal Efficiency
(SEDBUK) (%)
30 79.4
40 78.4
50 78.0
60 78.5
70 78.2
80 79.0
This value is used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been
calculated have been certified by 0086.
SEDBUK Declaration For Solo 3 PFL
All Models
121mm
Top of Outercase