Technical data

5.0 Installation
15
5.2 Fan Outlet Restrictor
Rear Flue only up to 500mm (19
5
/
8
in)
1. Release the four latches holding the
combustion box door (Fig 18). Remove the
combustion box door by pulling forward (Fig. 17).
2. Release the 5-pin electrical plug connecting the
pressure switch and fan (Fig. 19). Withdraw the
fan assembly by pulling forwards from the top
edge (Fig. 17).
3. Take the sheetmetal restrictor (supplied in the
kit of parts), check that the number stamped on
the restrictor matches the appliance (e.g. 50
stamped on the restrictor is for PFL 50 appliance).
4. Fit the restrictor to the fan outlet flange,
bending the 3 lugs equally ensuring the restrictor
seals against the fan outlet flange (Fig. 20).
5. Re-assemble the fan assembly and combustion
box door ensuring that the flexible tubes from the
fan unit to the pressure switch are routed correctly
and that they are not kinked or flattened
(Fig. 21).
Fan Outlet Flange
Fan Outlet Restrictor
Fig. 19
Fig. 18
Fig. 17
Fig. 20
Flexible Tubes
Fig. 21
Combustion Box Door
Fan Assembly
Fan Assembly
Pressure
Switch