Installation manual
GENERAL WARNINGS:
T
he solar system should never be left with water in and not fully commissioned. If
commissioning can not take place, the unit should be left with no water content or the
collectors covered.
Both circuits contain unvented systems. Please ensure all relevant relief valves and
associated expansion equipment are fitted. This includes any equipment not supplied by
Andrews Water Heaters. The installation should only be carried out by a competent person
as per the Building Regulations.
Solar collectors are both high temperature water and steam generators. Therefore high
pressures and temperatures can be generated. The collectors and associated equipment
have been designed for these conditions. However the collectors should be treated with
precautions associated with high temperature/pressure systems.
Full Health and Safety regulations should be followed for all aspects of installation.
IMPORTANT INSTALLATIONS NOTES
1. ENSURE THE INSTALLATION IS CARRIED OUT AS PER THE APPROPRIATE
SYSTEM SCHEMATIC AND THAT ALL EQUIPMENT IS INCLUDED AND
INSTALLED CORRECTLY.
2. COLLECTORS ARE INSTALLED AT THEIR OPTIMUM ORIENTATION AND
ANGLE TO MAXIMISE SOLAR CONTRIBUTION. SEE TECHNICAL
SPECIFICATION SECTION.
3. ENSURE PIPE-WORK IS AN APPROPRIATE SIZE FOR FLOW RATES.
4. FOR COPPER PIPE-WORK ONLY BRAZED OR COMPRESSION/SCREWED
CONNECTIONS SHOULD BE USED, APPROPRIATE FOR THE HIGH
TEMPERATURES >215°C.
5. APPROPRIATE EXPANSION VESSELS AND RELIEF VALVES SHOULD BE
INSTALLED ON BOTH SOLAR AND DOMESTIC HOT WATER SIDES OF THE
SYSTEM.
6. THE SOLAR SYSTEM SHOULD ONLY BE FILLED USING THE SUPPLIED
GLYCOL/WATER MIX. IT IS RECOMMENDED THAT THIS IS USED FOR TEST
FILLS DUE TO THE DIFFICULTIES IN DRAINING DOWN THE ENTIRE WATER
CONTENT IN THE COLLECTORS.
7. THE ANDREWS SOLARflo SYSTEM REQUIRES 230V, 4AMP (OTHER
SYSTEMS MAY REQUIRE MORE). THE POWER SUPPLY TO THE
CONTROLLER MUST BE ABLE TO BE ISOLATED CLOSE TO THE UNIT. A
SEPERATE 230V PLUG SOCKET MUST ALSO BE AVAILABLE FOR
COMMISSIONING.
IF IN DOUBT ASK
INSTALLATIONSECTION 3
8
Please refer to the Technical Specification Appendix for details of the individual equipment.
The overall specification sheet will indicate specific supply of the system supplied.
PRIMARY
SYSTEMS