Technical data
47
14.0 Changing Components
© Baxi Heating UK Ltd 2007
14.23 Secondary Heat Exchanger) (Fig. 80)
1. Drain the primary circuit
2. Undo the four screws securing the right hand case panel.
Remove the panel.
3. Prise the connecting clips from the heat exchanger return
pipe and the boiler return pipe. Remove the pipes.
4. Slacken the screws on the left hand fan spigot outlet pipe
clamp. Ease the clamp to the right.
5. Remove the nut securing the elbow to the secondary heat
exchanger. Draw the elbow and outlet pipe forwards.
6. Remove the secondary heat exchanger from the outer
drum by easing it forward.
7. Reassemble in reverse order of dismantling.
14.24 Flue Overheat Thermostat (Fig. 81)
NOTE: The flue overheat thermostat includes a reset
button. Check that the thermostat will not reset before
replacing.
1. Remove the fan spigot outlet pipe from the fan and elbow.
2. Pull the two wires off the terminals on the flue overheat
thermostat. Unscrew the thermostat from the adaptor in the
outlet elbow.
3. Reassemble in reverse order of dismantling.
Ease Fan Spigot Outlet Pipe
Clamps Inwards
Fan Spigot Outlet Pipe
Overheat Thermostat
Fan Spigot Outlet
Pipe Clamp
Fan Spigot
Outlet Pipe
Secondary
Heat Exchanger
Outer Drum
Boiler Return Pipe
Pipe Connecting Clip
Elbow
Heat Exchanger
Return Pipe
Fig. 80
Fig. 81
28 model
18 & 24
model