Technical data
18.0 32 kW Model Supplement
© Baxi Heating UK Ltd 2012
Outercase Dimensions
Casing Height - 763mm
Overall Height Inc Flue Elbow - 923mm
Casing Width - 450mm
Casing Depth - 355mm
Expansion Vessel - (For Central Heating only.
Integral with appliance)
bar
Min Pre-charge Pressure 0.5
32 model
litre
Max Capacity of
CH System 155
Primary Water Content
of Boiler (unpressurised) 2.8
Injector
32 model mm 5.8
Heat Input CH (Net) Max Min
32 model kW 32 4.6
Heat Output CH (Non-Condensing)
Max Min
32 model kW 32 4.6
Appliance Category CAT II
2H
3P
Heat Output CH (Condensing)
Max Min
32 model kW 33.8 5
Power Consumption
32model W 132
Inlet Pressure (Natural Gas - G20)
mbar 20
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
32 model m
3
/h 3.40
Inlet Pressure (Propane - G31)
mbar 37
NATURAL GAS ONLY !
PROPANE ONLY !
Max Gas Rate (Propane - G31)
(After 10 mins)
32 model kg/h 2.49
Weights
(32 model)
Packaged Boiler Carton 42.5kg
Installation Lift Weight 37.5kg
150mm* Min
763mm
450mm
175 mm Min (300mm
Min if using 80/125mm
flueing system)
5mm Min
Fig. 8
5mm Min
Appliance Type C
13
C
33
C
43
C
53
5mm Min
450mm Min
For Servicing
Purposes
In Operation
At least 1.5°
355mm
(345mm with flap removed)
* This is MINIMUM recommended dimension. Greater
clearance will aid installation and maintenance
47