10.0 Electrical
© Baxi Heating UK Ltd 2012
Mains
Supply.
Pump
E
N
L
E
N
L
E
CH1
N
L
(Out)
(On)
(Out)
(Out)
Boiler On (In)
CH2
(On)
C/S
(Out)
C/S
(In)
DHW
(On)
DHW
(Off)
(In)
E
N
Valve
Valve
Out Door
Sensor
(Out)
(In)
Cylinder
Sensor
Out Door
Sensor
(Out)
Cylinder
Sensor
(+12v)
Back
Light
Ground
(0V)
Data
Signal (+V)
Fused
8
Fused
8
Fused
8
CH2
CH1
DHW
2 Port
Valve
2 Port
Valve
2 Port
Valve
Wall Cradle
gr
o
gr
o
gr
o
Key
o - Orange
gr - Grey
Isolate
Isolate
Isolate
3
2
1
br
b
g/y
br
br
2nd Wall Cradle
Megaflo
10.10 S-Plan with 2nd Heating Circuit
1. The appliance MUST have a permanent Live/Neutral/Earth
connection. The pump must be connected to the appliance as
shown.
2. Set parameter 5700 to ‘3’ for two heating circuits - see section
11.3.k.
3. To control the second heating circuit a second THINK
Controller is required – this is available as an optional extra. For
guidance on installing the second THINK Controller see section
11.3 paragraph k.
Use either a cylinder sensor or thermostat as in section 10.8&9.
Intelligent Installations