Technical data
42
10.0 Electrical
© Baxi Heating UK Ltd 2012
Mains
Supply.
Pump
E
N
L
E
N
L
E
CH1
N
L
(Out)
(On)
(Out)
(Out)
Boiler On (In)
CH2
(On)
CT
(In)
CT
(Out)
DHW
(On)
DHW
(Off)
(In)
E
N
Valve
Valve
Out Door
Sensor
(Out)
(Out)
Out Tank
Sensor
Out Door
Sensor
(In)
In Tank
Sensor
(+12v)
Fused
8
Fused
8
Fused
8
3 Port
Spring Return Valve
Wall Cradle
br
b
g/y
Key
br - Brown
b - Blue
g/y - Green/Yellow
Back
Light
Ground
(0V)
Data
Signal (+V)
3
2
1
10.7 W-Plan with DHW cylinder thermostat
1. The appliance MUST have a permanent Live/Neutral/Earth
connection. The pump must be connected to the appliance as
shown.
2. Set parameter 5700 to ‘2’ for one heating circuit - see section
11.3.k.
3. The rest port of the 3 port valve needs to be connected to
the central heating circuit so that the valve is driven to the DHW
position. It is most likely that the three port valve on an existing
primary circuit will have to be turned round.
4. The DHW set point on the THINK Controller must be the
same as the thermostat set point on the cylinder. If this is not
done the DHW temperature may not be achieved or the
recovery time will be increased.
NOTE: It is not possible to operate a second heating circuit with
a W-Plan system.
Intelligent Installations