Technical data
40
10.0 Electrical
© Baxi Heating UK Ltd 2012
Mains
Supply.
Pump
E
N
L
E
N
L
E
CH1
N
L
(Out)
(On)
(Out)
(Out)
Boiler On (In)
CH2
(On)
CT
(In)
CT
(Out)
DHW
(On)
DHW
(Off)
(In)
E
N
Valve
Valve
Out Door
Sensor
(Out)
(Out)
Out Tank
Sensor
Out Door
Sensor
(In)
In Tank
Sensor
Fused
8
Fused
8
Fused
8
V1
3 Port
Mid Position Valve
Wall Cradle
w
o
gr
b
g/y
Key
w - White
o - Orange
gr - Grey
b - Blue
g/y - Green/Yellow
Back
Light (+12v)
Ground
(0V)
Data
Signal (+V)
3
2
1
10.5 Y-Plan with DHW cylinder Thermostat
1. The appliance MUST have a permanent Live/Neutral/Earth
connection. The pump must be connected to the appliance as
shown.
2. Set parameter 5700 to ‘2’ for one heating circuit - see section
11.3.k.
3. The DHW set point on the THINK Controller must be the
same as the thermostat set point on the cylinder. If this is not
done the DHW temperature may not be achieved or the
recovery time will be increased.
NOTE: It is not possible to operate a second heating circuit with
a Y-Plan system.
Intelligent Installations