Technical data

39
10.0 Electrical
© Baxi Heating UK Ltd 2012
Mains
Supply.
Pump
E
N
L
E
N
L
E
CH1
N
L
(Out)
(On)
(Out)
(Out)
Boiler On (In)
CH2
(On)
C/S
(Out)
C/S
(In)
DHW
(On)
DHW
(Off)
(In)
E
N
Valve
Valve
Out Door
Sensor
(Out)
(In)
Ta nk
Sensor
Out Door
Sensor
(Out)
Ta nk
Sensor
Fused
8
Fused
8
Fused
8
V1
3 Port
Mid Position Valve
Wall Cradle
w
o
gr
b
g/y
Key
w - White
o - Orange
gr - Grey
b - Blue
g/y - Green/Yellow
Back
Light (+12v)
Ground
(0V)
Data
Signal (+V)
3
2
1
10.4 Y-Plan with DHW cylinder sensor
1. The appliance MUST have a permanent Live/Neutral/Earth
connection. The pump must be connected to the appliance as
shown.
2. Set parameter 5700 to ‘2’ for one heating circuit - see section
11.3.k.
NOTE: It is not possible to operate a second heating circuit with
a Y-Plan system.