Technical data
10
© Baxi Heating UK Ltd 2012
4.0 Technical Data
4.1 Ecogen 24/1.0 and Ecogen 24/1.0 LPG
Flue Terminal Diameter 100mm
Dimensions Projection 125mm
Outercase Dimensions
Casing Height - 950mm
Overall Height Inc Flue Elbow - 1135mm
Casing Width - 450mm
Casing Depth - 426mm
Central Heating Primary Circuit
Sealed System only
bar
Safety Discharge 3
Max Operating 2.5
Min Operating 0.5
Recommended Operating Range 1-2
Hydraulic Resistance
See graph below
Connections copper tails
Gas Supply - 15mm
Central Heating Flow - 22mm
Central Heating Return - 22mm
NO
x
Class 5
Clearances
Above Casing 300 mm Min (horizontal flue)
200 mm Min (vertical flue)
Below Casing 200 mm Min
Front 450 mm Min (For Servicing)
Front 5 mm Min (In Operation)
L.H. Side 5 mm Min
R.H. Side 60 mm Min (In Operation)
Electrical Supply 230V~ 50H
z
(Appliance must be connected to an
earthed supply)
Power Consumption
24 model 150W
Electrical Protection
IP X4
Internal Fuse Rating 3.15A
for pump & diverter valve
Condensate Drain
To accept 21.5mm (
3
/
4
in) plastic waste pipe
External Fuse Rating 13A
Weights
Packaged Boiler Carton 117kg
Installation Lift Weight 110kg
Frost Thermostat 5° C
0
Water Flow Rate (litres/min)
Pump Head (metres)
Appliance Hydraulic Resistance Chart
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
510152025
Heat Input (Net) Max Min
kW 25.3 3.7
Heat Output (Non-Condensing)
Max Min
kW 23.7 3.2
Appliance Type C
13
C
33
C
53
Heat Output (Condensing)
Max Min
kW 24.3 3.3
Heat Input (Gross) Max Min
kW 28.1 4.1
Appliance Category CAT I
2H
Inlet Pressure (Natural Gas - G20)
mbar 20
Max Gas Rate (m
3
/hr)
Both 2.68 Engine 0.82 Supplementary 1.86
Injector (mm)
Engine 4.1 Supplementary 5.6
Country - GB/IE - Natural Gas
Appliance Category CAT I
3P
Inlet Pressure (LPG - G31)
mbar 37
Max Gas Rate (m
3
/hr)
Both 1.04 Engine 0.32 Supplementary 0.72
Injector (mm)
Engine 3.0 Supplementary 4.0