7.7 Flue Dimensions
The standard horizontal flue kit allows for flue lengths
between 100mm and 1m from elbow to terminal
(Fig. 12).
The maximum permissible equivalent flue length is:
Instant 80e 5 metres
Instant 105e 4 metres
NOTE: Each additional 45° of flue bend will
account for an equivalent flue length of 0.5m.
eg. 45° = 0.5m, 90° = 2 x 45° = 1m etc.
7.8 Flue Terminal Trim
1. Once the flue is secure the trim can be fitted if
required.
2. Remove the protective backing from the adhesive
seal. Apply the seal to the rear of the trim flange
(Fig. 13).
3. Locate the trim over the flue terminal and push it
back to the wall to compress the seal (Fig. 14).
7.9 Terminal Guard (Fig. 15)
1. When codes of practice dictate the use of terminal
guards, they can be obtained from most Plumbers’ and
Builders’ Merchants.
2. There must be a clearance of at least 50mm between
any part of the terminal and the guard.
3. When ordering a terminal guard, quote the appliance
name and model number.
3. The flue terminal guard should be positioned
centrally over the terminal and fixed as illustrated.