Technical data
This boiler is fitted with a flow switch
interlock that prevents it from firing when
the heating demand is satisfied.
1.1 Description
1. The Baxi Combi 130 HE is a fully automatic gas
fired wall mounted condensing combination boiler.
It is room sealed and fan assisted, and will serve
central heating and mains fed domestic hot water.
2. The boiler is preset to give a maximum output of
23.9 kW (81,500 Btu/h) for central heating and
39.0 kW (133,000 Btu/h) for hot water. In central
heating mode the boiler will automatically adjust
down to 10.6 kW (36,000 Btu/h) according to
system load.
3. It is designed for use on Natural Gas (G20) only.
4. Check the local supply conditions before
installation.
5. The boiler is suitable for use only on fully
pumped sealed heating systems. Priority is given
to domestic hot water.
6. A label giving details of the model, serial number
and Gas Council number is situated on the rear of
the lower door panel (Fig. 1).
7. The boiler data badge is positioned on the air
box door (Fig. 2).
8. The boiler is intended to be installed in
residential / commercial / light industrial E.M.C.
environments on a governed meter supply only.
9. The boiler must be installed with one of the
purpose designed flues such as the standard
horizontal flue kit, part n
o
236921.
1.2 Important Information
Man-made mineral fibre
• Some component parts of this appliance
(insulation pads, gaskets and rope seals) are
manufactured from man-made mineral fibre.
• Prolonged or excessive exposure to this material
may result in some irritation to the eyes, skin or
respiratory tract.
• It is advisable to wear gloves when handling
these items.
• Irritant dust will only be released from the items if
they are broken up or subjected to severe
abrasion. In these instances a suitable dust mask
and goggles should be worn.
• Always thoroughly wash hands after installation,
servicing or changing components.
• When disposing of any items manufactured from
man-made mineral fibre care must be exercised.
• If any irritation of the eyes or severe irritation of
the skin is experienced seek medical attention.
1.0 Introduction
5
Fig. 1
Fig. 2
Lower Door Panel
Air Box Door
Data Badge