Technical data

Genesis Baxi Heating Ltd.
44 - 45
SITE REQUIREMENTS – Page 14
Ventilation of Compartments
Where the appliance is installed in a cupboard or
compartment, air vents are required (for cooling purposes) in
the cupboard or compartment at high and low level which
may communicate with a room or direct to outside air.
Detailed recommendations for air supply are given
in BS 5440: Part 2.
An existing cupboard or compartment may be used,
provided that it is modified for the purpose.
Recommendations for air supplies and details of -essential
cupboard compartment design are given In BS 5440:Part2.
NOTE:-Both air vents must communicate with the same
room or both be on the same wall to outside air.
Genesis 80
Position of Air from Air direct
Air Vent Room from Outside
High 257cm
2
(39in
2
) 128cm
2
(19.5in
2
)
Low 257cm
2
(39in
2
) 128cm
2
(19.5in
2
)
Genesis 96
Position of Air from Air direct
Air Vent Room from Outside
High 311cm
2
(48.2 in
2
) 156cm
2
(24.1 in
2
)
Low 311cm
2
(48.2 in
2
) 156cm
2
(24.1 in
2
)
Gas Supply
The-gas installation should be in accordance with BS 6891.
The connection to the appliance is a 22mm copper tail
located at the rear of the gas cock.
Ensure that the pipework from the meter to the appliance is
of adequate size. Do not use pipes of a smaller diameter
than the appliance gas connection.
Electrical Supply
External wiring must be correctly earthed, polarized and in
accordance with current I.E.E. Wiring Regulations.
The mains supply is 230V - 50Hz fused at 3A.
NOTE:-The method of connection to the electricity
supply must facilitate complete electrical isolation of the
appliance.
Connection may be via a fused double-pole isolator with a
contact separation of at least 3mm in all poles and servicing
the appliance and system controls only.