Instruction Manual

TP10456-EN PAGE 22
16.0 RUN FAULT ERROR MESSAGES
These error messages may occur during setup or a production run.
ERROR MESSAGE REMARKS
INHIBIT
1st Station is not running, check wiring to controller board.
DOUBLE SHEET
Remove the double sheet, check sensor, wiring to controller board
17.0 CONTROLLER LED LIST
The following is a list of LEDs and their associated circuit located on the controller.
18.0 DIAGNOSTIC PROGRAM
The diagnostic program contains several routines that will test the operator keypad, test the controller
sensors, test the controller output circuits and test the panel indicators.
D1 Pile Reload Sensor
D2 Table Enable
D6 Direction
D10 Pile Height Sensor
D11 Double Sheet Detector
D13 Table Up Safety Limit Switch
D14 Table Down Safety Limit Switch
D15 Table Down Limit Switch
D18 Feed Enable
D19 Speed
D21 Pump
D23 Motor AC
D35 +12 Vdc Switched
D40 +5 Vdc Logic Power
D42 +12 Vdc Power
LED
DESIGNATION
ASSOCIATED
CIRCUIT
18.0.1 PILE FEEDER KEYPAD SWITCH TESTS
This test will provide a way of checking the operation of the switches on the operator keypad. During
this test, all outputs from the motors, sensors, etc. are turned off. Also, you may exit this diagnostic program at
any time by pressing the Diagnostic Key, 5.