Manual

PAGE 29 TP10496
8.0 OPERATOR PANEL KEY & INDICATOR FUNCTION DESCRIPTIONS
1.) Pile Feeder Stop Key Disables the controller outputs
2.) Pile Feeder Start Key Initiates startup diagnostic and enables controller outputs
3.) Sheet Mode Key Selects between production mode and single sheet mode
4.) Sheet Start Key Initiates feeding of sheets by energizing the vacuum solenoid
5.) Diagnostic Key Initiates the diagnostic program
6.) Reset Key Initiates a reset function for counters or error functions
7.) Enter Key Enters data into a function memory
8.) Pile Table Down Key Initiates the table down function
9.) Pile Table Stop Key Initiates the table stop function
10.) Pile Table Up Key Initiates the table up function (key must be held for continuous
table movement)
11.) Batch Set Key Initiates the batch counter set up and resets the batch counters
12.) Counter Key Resets the total counter and the batch counters
13.) Parameter Down Key Decrement various parameters
14.) Parameter Up Key Increment various parameters
15.) Sheet Gap Key Initiates the adjustability of the sheet gap
16.) Sheet Count Input Indicates when the sheet sensor detects a target (sheet)
Indicator
17.) Batch Interrupt Output Indicates when the feeding is interrupted at the batch point
Indicator
18.) Sheet Feed Solenoid Output Indicates the output signal to the vacuum solenoid to feed a sheet
Indicator
19.) Pile Table Status Indicator Indicates when the feed table is in motion
20.) Pile Feeder Ready Indicator Indicates when Pile Feeder is powered up and ready for use.